| :: Manufacturer Partners :: Featured Products
|
Temperature Transmitters
|
|
| Accutech |
| AI-1500 |
 |
| Thermocouple, RTD, Resistance & mVDC Inputs |
| HART or Removable Local Display Set-up | |
| Pyromation |
| Series 440 |
 |
100 Ohm Platinum RTD Input |
Pyromation Software for Set-up | |
| Pyromation |
| Series 442 |
 |
| Thermocouple, RTD, Resistance & mVDC Inputs |
HART for Set-up | |
Level Transmitters
| Ametek |
| 575 |
 |
| Submersible Hydrostatic Pressure with Snub Nose |
| Water & Liquids |
| 2-Wire 4-20 mADC Output | |
| Ametek |
| 575 P |
 |
| Submersible Hydrostatic Pressure with Protected Flush Diaphragm |
| Waste Water & Slurry |
| 2-Wire 4-20 mADC Output | |
| Dwyer |
| CLT |
 |
| Tank Top Mounting with Float on Brass or SS Stem |
| Liquids |
| 4-20 mADC or 0 to (10-30) VDC | |
| STI |
| LPU-2127 |
 |
| Loop Powered Ultrasonic Level Sensor |
| Liquids & Solids |
| 2-Wire 4-20 mADC & Local Display | |
| Bindicator |
| Cap-Level II A |
 |
| Radio Frequency Capacitance Using Rigid or Cable Probe |
Liquids
|
2-Wire 4-20 mADC Output | |
| Bindicator |
| GP 4 & Mark 4 Yo-Yo |
 |
| Tank Top Unit with Weight & Retractable Cable |
| Solids, Liquids & Liquid / Solid Interface |
| 4-20 mADC, RS-485(MODBUS) & Local Readout | |
| Bindicator |
| Phase Tracker |
 |
| Tank Top Unit with Cable using Phase Difference Technology |
| Solids & Liquids -Ignores Dust, Vapors & Foam |
| 4-20 mADC, RS-232, Modem, Relay & Local Readout | |
| Bindicator |
| SonoTracker |
 |
| Tank Top Mounting Using Ultrasonic Technology |
| Solids & Liquid Level, Open Channel Flow and Differential Level |
| 4-20 mADC, RS-485, Allen Bradley RIO, Profibus & Local Readout | |
Flow Transmitters
|
|
| Barksdale |
UQS7
|
 |
| Ultrasonic |
0.1 to 45 GPM Water-based Liquids
|
| 3/4" to 1 1/4" Pipe |
250:1 Turndown
|
+/- 2.5% of Full Scale Accuracy
| |
| Bindicator |
SonoTracker
|
 |
| Ultrasonic |
Open Channel Flow with Weir or Flume
|
| 2" to 100" Depth |
10:1 Turndown
|
+/- 1% of Rate Accuracy
| |
| Kobold |
DMI PMG
|
 |
| Magetic Inductive |
DMI: 0.7 to 320 GPM PMG: 0.2 to 10,000 GPM Liquids & Slurries |
| 3/8" to 12" Pipe |
| 12:1 to 30:1 Turndown Depending on Line Size |
DMI: +/- 1.5% or 3% of Rate Accuracy PMG: +/- 0.25% or 0.5% of Rate Accuracy | |
| Dwyer |
| Series 641 Air Velocity |
 |
| Heated Mass Flow Sensor |
Up to 15,000 FPM Air
|
| 6" to 36" Insertion Probe |
| -40 to +212ºF |
| 100 PSIG Maximum |
| +/-3% (32 to 122ºF) or 4% of Full Scale Accuracy | |
| Dwyer |
| Series AVU Air Velocity |
 |
| Heat Loss Sensing Element |
Up to 3,150 FPM Air
|
| 9" Insertion Probe |
| 32 to +122ºF |
| 2 PSIG Maximum |
+/-5% of Full Scale Accuracy
| |
| Dwyer |
| Series PF & PFS Air Velocity |
 |
| Heated Mass Flow Sensor |
PF: Up to 6,000 SFPM Air PFS: Up to 15,000 SFPM Air |
| 13" Insertion Probe |
| -40 to +250ºF |
| 150 PSIG Maximum |
+/-1% of Full Scale Accuracy
| |
| Weber |
| Type 3205 vent-captor |
 |
| Calorimetric principle |
Up to 3,800 FPM Air
|
| 2" Insertion Probe |
| -4 to +160ºF |
| 145 PSIG Maximum |
+/-5% of Full Scale Accuracy
| |
| Weber |
Type 3302 vent-captor
|
 |
| Calorimetric principle |
| Up to 3800 FPM Air |
| 8, 12, 18, 22 & 28 mm tubing |
| -4 to +160ºF |
| 145 PSIG Maximum |
| +/-5% of Full Scale Accuracy | |
|
| Weber |
Types 4114 30 & 4115 30 flow-captor |
 |
| Calorimetric principle |
| Up to 6.5 FPS - Liquids |
| 2.14" or 2.4" Insertion Probe |
| 14 to +176ºF |
| 435 PSIG Maximum |
| +/-5% of Full Scale Accuracy | |
| Weber |
Type 4311 30 flow-captor
|
 |
| Calorimetric principle |
| Up to 3.3 FPS - Liquids |
| 8, 12, 18, 22 & 28 mm tubing |
| 14 to +176ºF |
| 435 PSIG Maximum |
| +/-5% of Full Scale Accuracy | |
Humidity and Oxygen Transmitters
| EdgeTech |
H-S Relative Humidity Transmitter |
 |
| Range: 10 to 95% RH (Operating: 40 to 160ºF) |
Accuracy: +/- 3% RH (30 to 80% RH)
|
Output: 0-10 VDC = %RH
|
| Wall, Duct or Outside Air Mounting | |
| EdgeTech |
| 600 Relative Humidity & Temperature Transmitter |
 |
Ranges: 0 to 100% RH -4 to +248ºF |
Accuracies +/- 2% RH (0 to 90% RH) +/-0.6ºF (-4 to +122ºF) |
Output(s): 4-20 mADC = %RH & Temperature
|
| Wall, Duct or Remote Mounting | |
| EdgeTech |
| 650 Precision Relative Humidity & Temperature Transmitter |
 |
Ranges: 0 to 100% RH -40 to +356ºF |
Accuracies +/- 1% RH (10 to 90% RH) +/-0.36ºF (-4 to +140ºF) |
Output(s): 4-20 mADC = %RH, Dew Point or g/k plus Temperature |
| Wall, Duct or Remote Mounting | |
| EdgeTech |
| WBL-200 Wireless Relative Humidity & Temperature Data Logger |
 |
Ranges: 0 to 100% RH -67 to +266ºF |
Accuracies +/- 2% RH (11 to 55% RH) +/-1.8ºF @ 77ºF |
| 20,000 Data Points On Board Data Logging. RS 232 & USB for Real Time Recording |
| Surface Mounting Enclosure | |
| EdgeTech |
| HTPB Series Multi-Parameter Humidity & Temperature Probes |
 |
Ranges: 5 to 95% RH -4 to +240ºF Temperature -76 to +203ºF Dew Point 0-200 PSIA Pressure |
Accuracy +/- 1% RH (5 to 95% RH)
|
| Outputs: RS 232 plus Three (3) 0-10 VDC = Selectable %RH, Dew Point, ppmv, ppmw, gr/lb, g/kg, Temperature or Pressure |
| Wall, Duct, 3/4" Compression Fitting or Remote Mounting | |
| EdgeTech |
| 6740 Series Humidity Transmitter in Compressed Air |
 |
Range: -76 to +86ºF Dew Point (Operating: 30" Hg Vacuum to 0 to 725 PSIG Pressure) |
Accuracy +/- 3.6ºF @ 23ºF Dew Point
|
Outputs: 4-20 mADC = Selectable Dew Point or ppmv plus 2 optional alarms
|
1/2" NPT Process Connection | |
| EdgeTech |
| Model 200 DewTrak Chilled Mirror Dew Point Transmitter |
 |
| Range: -40 to +140ºF Dew Point (Operating: -40 to +162ºF Temperature; 1,000 PSIG Maximum Pressure) |
Accuracy +/- 1ºF Dew Point
|
Outputs: 4-20 mADC = Dew Point, %RH, Wet Bulb or Grains per Pound;Optional Temperature
|
| Wall, Duct, 1 1/4" NPT or Aspirator Mounting | |
| EdgeTech |
OxyTrans Oxygen Transmitter |
 |
Oxygen Ranges: 0-100, 0-1,000 or 0-10,000 PPM 0-1 or 0-25% (Operating: -40 to +162ºF)
|
Accuracy: +/- 2% FSD at Constant Temperature +/- 5% FSD from 32 to 122ºF |
Outputs: 4-20 mADC, Alarm & Local Display
|
| Compression Fittings with Flow-Through Measuring Cell | |
| |